Production program

  • Axial fan LAZ 250 - LAZ 315
    Fan for wall or partition wall installation
    art_1_g_00

    Impeller diameter: 250 mm or 315 mm.

    Air flow:
    LAZ 250 – 860 m³/h
    LAZ 315 – 1.440 m³/h

    Documentation:

    Axial fan AVL 355 – 630
    Type 1 – Square casing – Wall mounted design
    art_2_g_00 art_2_d_01
    Type 2 – Cylindrical casing – Duct mounted design (up to 500 mm)

    Impeller diameter: from 355 mm to 630 mm.
    Air flow: from 900 m³/h up to 10.000 m³/h

    Documentation:

    Roof fans SV
    Type SVH2 – horizontal outlet
    Type SVV2 – vertical outlet
    Type SVK2 – vertical outlet

    Air flow: up to 52.000 m³/h

    We also produce roof fans in the explosion proof design – EX SVK2

    Documentation:art_3_d_01art_3_d_02art_3_g_00

    Air heaters GNA2, GNJ2, EGN
    Type GNA2 – Cu-Al heat excanger, four sizes
    art_4_g_00Heat output: from 12 up to 80 kW; water system 80/60°C

    Type GNJ2 – steel heat excanger, four sizes
    Heat output: from 20 up to 153 kW; water system 80/60°C

    Typ EGN – Electric heater, two sizes
    Heat output: from 4 up to 20 kW

    We also produce air heaters in the explosion proof design – EX GN A/J

    Documentation:

  • High – pressure fans 101,103, 133 CV
    Size:
    art_5_g_00
    101 CV 80 to 101 CV 710 (ISO R 20)
    103 CV 100 to 103 CV 900 (ISO R 20)

    Air flow: 36 to 100.000 m³/h;
    intake connection from Ø80 mm up to Ø900 mm
    Total pressure: 400 up to 10.000 Pa

    We also produce radial fans in the explosion proof design – EX CV

    Documentation:

    High pressure fans with big Air flows 104, 134 CV
    Size:
    art_6_g_00
    104 CV 125 to 104 CV1120 (ISO R 20)

    Air Flow: 144 up to 145 000 m³/h;
    intake connection from Ø125 mm up to Ø1.120 mm
    Total pressure: 400 up to 8.000 Pa

    We also produce radial fans in the explosion proof design – EX CV

    Documentation:

    Middle pressure fans with big Air flows 105,106, 135,136 CV
    Size:
    art_7_g_00
    105 CV 160 to 105 CV 1400 (ISO R 20)
    106 CV 200 to 106 CV 1800 (ISO R 20)

    Air Flow: 220 up to 220.000 m³/h;
    intake connection from Ø160 mm up to Ø1.800 mm
    Total pressure: 250 up to 6.000 Pa

    We also produce radial fans in the explosion proof design – EX CV

    Documentation:

  • Axial fan AVS (AVSV) 400 -– 1600
    AVS – fan without guide vaneart_8_g_00 art_8_d_02 art_8_d_01
    AVSV – fan with guide vane

    impeller diameter:
    od 400 mm do 1250 mm. (AVS)
    od 400 mm do 1600 mm. (AVSV)

    Air flow:
    od 2.000 m³/h do 150.000 m³/h (AVS)
    od 2.000 m³/h do 300.000 m³/h (AVSV)

    Total pressure:
    do 1200 Pa (AVS)
    do 1600 Pa (AVSV)

    We also produce axial fans in the explosion proof design – EX AV

    Documentation:

    Axial fan with guide vane N-AVV-D/K 630 – 2240
    Impeller diameter:
    art_10_g_00
    from 630 mm up to 2.240 mm (ISO R 20)

    D/K – long or short blades

    Flow: up to 450.000 m³/h
    Total pressure: up to 4.500 Pa

    We also produce axial fans in the explosion proof design – EX AV

    Documentation:

    Jet fans for longitudinal tunnel ventilation
    Diameter:
    art_12_g_00
    from 500 mm up to 1.600 mm (ISO R 20)

    Air flow: up to 200.000 m³/h

    Possible design is with one way or reversible air flow.

    We also produce axial fans in the explosion proof design – EX AV

    Documentation: Please contact us for a specific documentation

     

  • Air conditioning units KC
    Modulary composed blocks.
    art_13_g_00 art_13_d_03 art_13_d_02

    Clima units are put together in 22 basic sizes,
    with the posibility to compose sections in variances
    from 1 to 11
    (heating, cooling, moistering, filtering, … )

    Capacity:
    from 1.500 m³/h up to 100.000 m³/h per unit

    Design:
    inside or outside (roof),
    vertical or horizontal

    Special design:
    EX – explosionproof
    h – hygienist

    Documentation:

     

  • Roof fan ODT - SVK2
    Roof-mounted design
    art_23_g_00 art_23_d_01

    Category: F400°C/120min

    Impeller diameter: 400 mm up to 1.000 mm (ISO R20)

    Designed for installation outside of the fire zone.

    Documentation:

     

    Axial fan ODT - AV / AVV / AVR / AVJ / AVJR
    Axial fan and electromotor for higher temperatures
    art_15_g_00 art_15_d_01
    ODT-AV – axial fan
    ODT-AVV – axial fan with guide vane
    ODT-AVR – reversible axial fan
    ODT-AVJ – axial garage JET fan – unidirectional
    ODT-AVJ-R – axial garage JET fan – reversible

    Category:
    300°C/120min
    400°C/120min

    Impeller diameter:
    400 mm up to 1.250 mm (ODT-AV)
    400 mm up to 1.600 mm (ODT-AVV)
    400 mm up to 1.250 mm (ODT-AVR)
    315 mm up to 400 mm (ODT-AVJ)
    355 mm up to 400 mm (ODT-AVJ-R)

    Designed for installation inside of the fire zone.

    Documentation:

    Centrifugal fan ODT - CV
    Radial fan with drive 3, 4
    art_18_g_00 art_18_d_01

    Category: 600°C/120min

    Impeller diameter: 315 mm up to 1.400 mm (ISO R20)

    Designed for installation outside of the fire zone.

    Documentation:

    Roof fan ODT - SVK
    Roof-mounted design
    art_19_g_00

    Category: 600°C/120min

    Impeller diameter: 400 mm up to 1.000 mm (ISO R20)

    Designed for installation outside of the fire zone.

    Documentation:

     

     

  • Heat exchangers type KG, RC
    Oval tubing heat exchangers:
    art_21_g_00 art_21_d_02

    KG 28 – lamell heat exchangers

    Spiral heat exchangers – coiled tubing:
    RC – normal lamell
    HC – high lamell

    APPLICATION:
    Heat exchangers are mainly used as:
    air heaters with warm or hot water, steam or oil – KG, RC, HC
    air coolers with cold water, water or oil coolers with air – KG, RC, HC

    Documentation:

     

     

    Systems for pneumatic transport, dust elimination, filtration, noise reduction
    We can design systems, perform or supervise the installation or engineering.Documentation: Please contact us for a specific documentation