Type 1 – Square casing – Wall mounted design Type 2 – Cylindrical casing – Duct mounted design (up to 500 mm)
Impeller diameter: from 355 mm to 630 mm. Air flow: from 900 m³/h up to 10.000 m³/h
Documentation:
Roof fans SV
Type SVH2 – horizontal outlet Type SVV2 – vertical outlet Type SVK2 – vertical outlet
Air flow: up to 52.000 m³/h
We also produce roof fans in the explosion proof design – EX SVK2
Documentation:
Air heaters GNA2, GNJ2, EGN
Type GNA2 – Cu-Al heat excanger, four sizes Heat output: from 12 up to 80 kW; water system 80/60°C
Type GNJ2 – steel heat excanger, four sizes Heat output: from 20 up to 153 kW; water system 80/60°C
Typ EGN – Electric heater, two sizes Heat output: from 4 up to 20 kW
We also produce air heaters in the explosion proof design – EX GN A/J
Documentation:
High – pressure fans 101,103, 133 CV
Size: 101 CV 80 to 101 CV 710 (ISO R 20)
103 CV 100 to 103 CV 900 (ISO R 20)
Air flow: 36 to 100.000 m³/h;
intake connection from Ø80 mm up to Ø900 mm Total pressure: 400 up to 10.000 Pa
We also produce radial fans in the explosion proof design – EX CV
Documentation:
High pressure fans with big Air flows 104, 134 CV
Size: 104 CV 125 to 104 CV1120 (ISO R 20)
Air Flow: 144 up to 145 000 m³/h;
intake connection from Ø125 mm up to Ø1.120 mm Total pressure: 400 up to 8.000 Pa
We also produce radial fans in the explosion proof design – EX CV
Documentation:
Middle pressure fans with big Air flows 105,106, 135,136 CV
Size: 105 CV 160 to 105 CV 1400 (ISO R 20)
106 CV 200 to 106 CV 1800 (ISO R 20)
Air Flow: 220 up to 220.000 m³/h;
intake connection from Ø160 mm up to Ø1.800 mm Total pressure: 250 up to 6.000 Pa
We also produce radial fans in the explosion proof design – EX CV
Documentation:
Axial fan AVS (AVSV) 400 -– 1600
AVS – fan without guide vane
AVSV – fan with guide vane
impeller diameter:
od 400 mm do 1250 mm. (AVS)
od 400 mm do 1600 mm. (AVSV)
Air flow:
od 2.000 m³/h do 150.000 m³/h (AVS)
od 2.000 m³/h do 300.000 m³/h (AVSV)
Total pressure:
do 1200 Pa (AVS)
do 1600 Pa (AVSV)
We also produce axial fans in the explosion proof design – EX AV
Documentation:
Axial fan with guide vane N-AVV-D/K 630 – 2240
Impeller diameter: from 630 mm up to 2.240 mm (ISO R 20)
D/K – long or short blades
Flow: up to 450.000 m³/h Total pressure: up to 4.500 Pa
We also produce axial fans in the explosion proof design – EX AV
Documentation:
Jet fans for longitudinal tunnel ventilation
Diameter: from 500 mm up to 1.600 mm (ISO R 20)
Air flow: up to 200.000 m³/h
Possible design is with one way or reversible air flow.
We also produce axial fans in the explosion proof design – EX AV
Documentation: Please contact us for a specific documentation
Air conditioning units KC
Modulary composed blocks. Clima units are put together in 22 basic sizes,
with the posibility to compose sections in variances
from 1 to 11
(heating, cooling, moistering, filtering, … )
Capacity:
from 1.500 m³/h up to 100.000 m³/h per unit
Design:
inside or outside (roof),
vertical or horizontal
Special design:
EX – explosionproof
h – hygienist
Documentation:
Roof fan ODT - SVK2
Roof-mounted design
Category: F400°C/120min
Impeller diameter: 400 mm up to 1.000 mm (ISO R20)
Designed for installation outside of the fire zone.
Documentation:
Axial fan ODT - AV / AVV / AVR / AVJ / AVJR
Axial fan and electromotor for higher temperatures ODT-AV – axial fan
ODT-AVV – axial fan with guide vane
ODT-AVR – reversible axial fan
ODT-AVJ – axial garage JET fan – unidirectional
ODT-AVJ-R – axial garage JET fan – reversible
Category:
300°C/120min
400°C/120min
Impeller diameter:
400 mm up to 1.250 mm (ODT-AV)
400 mm up to 1.600 mm (ODT-AVV)
400 mm up to 1.250 mm (ODT-AVR)
315 mm up to 400 mm (ODT-AVJ)
355 mm up to 400 mm (ODT-AVJ-R)
Designed for installation inside of the fire zone.
Documentation:
Centrifugal fan ODT - CV
Radial fan with drive 3, 4
Category: 600°C/120min
Impeller diameter: 315 mm up to 1.400 mm (ISO R20)
Designed for installation outside of the fire zone.
Documentation:
Roof fan ODT - SVK
Roof-mounted design
Category: 600°C/120min
Impeller diameter: 400 mm up to 1.000 mm (ISO R20)
Designed for installation outside of the fire zone.
Documentation:
Heat exchangers type KG, RC
Oval tubing heat exchangers:
KG 28 – lamell heat exchangers
Spiral heat exchangers – coiled tubing:
RC – normal lamell
HC – high lamell
APPLICATION:
Heat exchangers are mainly used as:
air heaters with warm or hot water, steam or oil – KG, RC, HC
air coolers with cold water, water or oil coolers with air – KG, RC, HC
Documentation:
Systems for pneumatic transport, dust elimination, filtration, noise reduction
We can design systems, perform or supervise the installation or engineering.Documentation: Please contact us for a specific documentation